원자력발전소 냉각재상실사고시 도장재 이물질의 사전차단을 위한 중간차단제 설계검토와 연구
이성명, 김원석 · 대한기계학회 춘추학술대회 · 2012
Interceptor is for the design structure at the containment building and is applying to the debris blockage likewise coating particle so that reduce the debris load to the strainer with state of ECCS LOCA. We have found that there are little studies for the existing interceptors and possibilities of researching work of design upgrade for debris blockage performance. It was performed by using the flow analysis and debris test. In conclusion, design variables(structure, height, hole punching) of interceptor have positive effect of debris blockage with 40% plus compared to existing one. It is primarily considered as the flow static status with low velocity for upgraded design at the front of interceptor.
Cited by 1 works.