화력발전보일러의 연소가스편류가 튜브의 건전성에 미치는 영향

정재진, 송정일 · 대한기계학회 춘추학술대회 · 2009

Flue gas flow deviation in upper furnace and convection tube bank is an important but a less reported issue in large-scale opposed wall fired boilers, since it related to the boiler control and reliability. Field test is conducted in this paper to study the relationship between flue gas flow deviation and tube reliability. Several items of field test, including flue gas temperature, NOx, CO and O₂, are monitored at boiler upper horizontal flue gas flow pass, upper convective rear pass and economizer exit by using a spatially distributed sensor and probe. The analysis results show that the flue gas flow deviation is directly affect to the tube erosion life and poor combustion conditions as a result of poorly controlled local fuel/air distribution within the boiler furnace are highly related to the flue gas flow deviation.