Noniterative synchronous machine parameter identification from frequency response tests
S. Henschel, Hermann W. Dommel · IEEE Transactions on Power Systems · 1999
In this paper, a method to identify synchronous machine parameters from standstill frequency response tests is presented. It is common practice to use iterative techniques first to match a set of time constants with the measured response, and then to solve a set of nonlinear equations to obtain the equivalent circuit parameters. However, there is a difficulty of specifying an initial parameter estimate before any iterations can commence. This problem is overcome by the method presented here, which is able to approximate machine parameters straightforwardly and without the need of iterating. It was found that the transfer functions produced by the calculated parameters very closely resemble the measured frequency responses. Should refinements of the solution become necessary, the obtained parameters will still serve as an excellent initial estimate for standard curve fitting procedures.
Cited by 24 works. doi:10.1109/59.761880
Authors
References
- Dynamic Models of Turbine Generators Derived From Solid Rotor Equivalent Circuits
- Development of Detailed Turbogenerator Equivalent Circuits from Standstill Frequency Response Measurements
- Development of Detailed Turbogenerator Equivalent Circuits From Standstill Frequency Response Measurements
- Adaptation and Validation of Turbogenerator Model Parameters Through On-Line Frequency Response Measurements
- Modeling of Solid Rotor Turbogenerators Part I: Theory and Techniques
- Synchronous Machine Models by Standstill Frequency Response Tests
- Supplementary Definitions&Associated Test Methods for Obtaining Parameters for Synchronous Machine Stability Study Simulations
- Synchronous Machine Models by Standstill Frequency Response Tests
- Small Signals, Large Signals, and Saturation in Generator Modeling
- Standstill Frequency Response Modeling and Evaluation by Field Tests on a 645 MVA Turbine Generator