콘크리트충전 강관(CFT)기둥의 소요 내화성능 확보방안

박수희, 류재용, 하영석 et al. · 대한건축학회 학술발표대회 논문집 - 구조계 · 2007

Concrete-filled steel tube(CFT) columns have a high fire resistance by heat storage effect of the concrete under fire. So, the decrease of external fire protection thickness for steel is possible. This research presented the simple estimation method for the fire resistance of CFT column with the decreased fire protection thickness. Also, we analyzed the comparison with existent researches about the estimation for the fire resistance of CFT column with the decreased fire protection thickness. Through this results, Validity for the estimation method of this research is investigated. The estimate of the fire resistance of CFT columns with the decreased fire protection thickness was compared with the external experiment results. Therefore the estimate values were verified. The CFT columns with decreased fire protection thickness secured enough fire resistance of 3 hours under fire.