개구부에 삽입한 수직평판이 헬륨·공기치환류에 미치는 영향

강태일 · 2003

This paper describes experimental investigations of helium-air exchange flow through single opening and partitioned opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with a small opening on top of test cylinder is used for experiments. An extimation method of mass increment is developed and applied to measure the exchange flow rate. An technique of flow visualization by match-zehnder interferometer is provided to recognize the exchange flows. Flow measurements are made with the opening, for partition ratins Hp/Hi in the range 0 to 1, where Hp and Hi are partition length and height of the opening, repectively. In the case of Hp/Hi of 0, flow passages of upward flow of the helium and downward flow of the air within the opening are unseparated(bidirectional) and the two flows interfere within the opening. The unseparated flow increases strength of flow resistance and therefore the exchange flow rate is minimum through range of the partition rations. Two flow zones, i.e., separated(unidirectional) flow zone and unseparated(bidirectional) flow zone, exist with increasing the partition length. The exchange flow rate increases with increasing the separated flow zone. It is found that a maximum exchange flow rate exists at Hp/Hi of 1. As a result of comparison of the exchange flow rates by changing the partition ratio, the fluids Interference in the unseparated zone is found to be an important factor on the helium-air exchange flow rate.

Cited by 0 works.