가변저항히트파이프 히트싱크에서 불응축가스량과 냉각공기가 열전달 성능에 미치는 영향

박기호, 이기우, 이욱현 et al. · 대한기계학회 춘추학술대회 · 2005

This study is to research the heat transfer characteristic in copper-water variable conductance heat pipes(VCHP) heat sink with a non-condensable gas and gas reservoir. the VCHP are composed with the copper tube and water as a working fluid and nitrogen as non-condensable gas(NCG). The VCHP was a copper tube 300~390 ㎜ long, 6 ㎜ outside diameter, the evaporator length was 80 ㎜. As a result, when the quantity of NCG was increased, there was an increase in the saturation vapor temperatures and evaporator surface temperature in early period of operation. The VCHP heat sink experiments have shown that the length of the active portion of the condenser zone is enlarged. As the input heat has loaded from 60 W to 80 W, the difference of the evaporator surface is lower than 6℃.

Cited by 0 works.