고온고압 환경에서의 시편 표점거리에 대한 직접적 변형량 계측을 위한 분리형 변위계측장치 개발
조선영, 정일석, 하각현 et al. · 대한기계학회 춘추학술대회 · 2009
Environmental fatigue test is conducted in high temperature and high pressure water environment to simulate the environment of operating nuclear power plant. In addition, FEM(finite element method) and direct strain measurement method have been used to measure the strain of specimen in a closed system. This study has developed a separated typed extensometer system that can directly measure the displacement of specimen's gage length for simulating more realistic test environment. Each part of separated extensometer are attached to upper and lower part of the specimen's gage length and measures the strain through LVDT sensor, which is individually connected with extensometer. Separated typed extensometer system is a smaller size of existing single typed extensometer system, which have been developed during previous study, and have complemented the disadvantage of usage and structural defects. This device can be applied to variety of material testings in high temperature and high pressure environments, replace the existing extensometer, and is expected to greatly contribute on acquiring more detailed test data.