국내 원전 분기배관의 열성층 및 열피로 평가

박정순, 최영환, 임국희 et al. · 대한기계학회 춘추학술대회 · 2010

Piping failures due to thermal fatigue have been widely reported in normally stagnant branch lines connected to reactor coolant system (RCS) in nuclear power plants (NPPs). Since the thermal fatigue due to thermal stratification was not considered in the piping fatigue design in old NPPs, it is important to evaluate the effect of thermal stratification on the integrity of branch lines and to prepare inspection and management program against the thermal fatigue. In this study, some computational fluid dynamic (CFD) analyses on the branch line connected to RCS in domestic NPP were performed to develop the regulatory guidelines for screening criteria and fluid analysis for the thermal fatigue evaluation. The result shows that both valve isolation and amount of leakage through valve can be used as technical bases for the screening criteria on the thermal fatigue analysis. The turbulent model, buoyancy model, and piping thickness should be adequately considered in the CFD analysis.