환경플랜트 탈취 덕트시스템의 흡입풍량 검증
조동환, 이동언, 문정환 et al. · 2006
This paper is intended to validate suction flow rates of a deodorization duct system equipped in an environmental plant. The duct system, which consists of a fan, a filter, a scrubber and ducts, removes odor generated during food waste processing. The suction fan in the present model is rated of 45,000 CMH in flow rate and 280 mmAq in static pressure. The flow distribution in the deodorization system is analyzed with the wellestablished T-method, yielding 47,548 CMH and 259 mmAq. The predicted suction flow rate of the fan agrees well with the design value, whereas those at the suction grilles deviate far from the initial design. It is estimated that to meet the target, the present model needs to be changed in the duct diameter or the installment of a damper before a suction grille.