Integrated Electroanatomic Mapping With Three-Dimensional Computed Tomographic Images for Real-Time Guided Ablations
Jun Dong, Hugh G Calkins, Stephen Barnett Solomon et al. · Circulation · 2006
BACKGROUND: New ablation strategies for atrial fibrillation or nonidiopathic ventricular tachycardia are increasingly based on anatomic consideration and require the placement of ablation lesions at the correct anatomic locations. This study sought to evaluate the accuracy of the first clinically available image integration system for catheter ablation on 3-dimensional (3D) computed tomography (CT) images in real time. METHODS AND RESULTS: After midline sternotomy, 2.3-mm CT fiducial markers were attached to the epicardial surface of each cardiac chamber in 9 mongrel dogs. Detailed 3D cardiac anatomy was reconstructed from contrast-enhanced, high-resolution CT images and registered to the electroanatomic maps of each cardiac chamber. To assess accuracy, targeted ablations were performed at each of the fiducial markers guided only by the reconstructed 3D images. At autopsy, the position error was 1.9+/-0.9 mm for the right atrium, 2.7+/-1.2 mm for the right ventricle, 1.8+/-1.0 mm for the left atrium, and 2.3+/-1.1 mm for the left ventricle. To evaluate the system's guidance of more complex clinical ablation strategies, ablations of the cavotricuspid isthmus (n=4), fossa ovalis (n=4), and pulmonary veins (n=6) were performed, which resulted in position errors of 1.8+/-1.5, 2.2+/-1.3, and 2.1+/-1.2 mm, respectively. Retrospective analysis revealed that a combination of landmark registration and the target chamber surface registration resulted in <3 mm accuracy in all 4 cardiac chambers. CONCLUSIONS: Image integration with high-resolution 3D CT allows accurate placement of anatomically guided ablation lesions and can facilitate complex ablation strategies. This may provide significant advantages for anatomically based procedures such as ablation of atrial fibrillation and nonidiopathic ventricular tachycardia.
Cited by 233 works. doi:10.1161/circulationaha.105.565200 Open-access PDF
Authors
- Jun Dong
- Hugh G Calkins
- Stephen Barnett Solomon
- Shenghan Lai
- Darshan Dalal
- Al Lardo
- Erez Brem
- Assaf Preiss
- Ronald David Berger
- Henry R. Halperin
- Timm Michael Dickfeld
References
- Longitudinal Data Analysis for Discrete and Continuous Outcomes
- Multiple Comparison Procedures
- Multiple Comparison Procedures
- Atrial Electroanatomic Remodeling After Circumferential Radiofrequency Pulmonary Vein Ablation
- Linear Ablation Lesions for Control of Unmappable Ventricular Tachycardia in Patients With Ischemic and Nonischemic Cardiomyopathy
- A Novel Method for Nonfluoroscopic Catheter-Based Electroanatomical Mapping of the Heart
- Nonfluoroscopic, in vivo navigation and mapping technology
- Role of Right Atrial Endocardial Structures as Barriers to Conduction During Human Type I Atrial Flutter
- Spectral Analysis Identifies Sites of High-Frequency Activity Maintaining Atrial Fibrillation in Humans
- Pulmonary Vein Anatomy in Patients Undergoing Catheter Ablation of Atrial Fibrillation