개선형 주방환기시스템 개발
이호준, 정연태 · 대한설비공학회 학술발표대회논문집 · 2001
Kitchen is the biggest pollution source that influences air quality of whole indoor space. But existing range hood system isn't sufficient to ventilation all odor materials, heat and pollutants. To improve this, a simultaneous supply and exhaust type range hood was developed in an advanced nation, but it has some weak points due to introduction of outdoor air. To make up for these, our company developed new simultaneous supply and exhaust type kitchen ventilation system using indoor air(COOVEN® SYSTEM). And COOVEN^® SYSTEM was compared with common range hood system in terms of temperature distribution and CO/CO₂ concentration of indoor. When the COOVEN^® SYSTEM was operated, temperature 2-3℃ and CO₂ equilibrium concentration about 1,000 ppm was low compared with common rage hood. Ventilation rate was estimated by CO₂ equilibrium and COOVEN^® SYSTEM was over than maximum 2.83 times as compared with common range hood system.
Cited by 0 works.