유동 균형을 고려한 유량 균일 분포에 관한 연구
성봉길, 김재원, 안은영 · 대한기계학회 춘추학술대회 · 2005
The present model is come from the cooling system of a refrigerator that includes a compressor, a coil-condenser and an axial flow fan for a forced blowing. The geometric arrangement of all components is fixed. However, the size and the position of both the inlet and outlet ports could be modified for the improved flow distribution around the compressor requires large flow rates for the effective cooling. The main methodology is PIV measurements of the flows inside the chamber. The optimal sizes and locations of the inlet and outlet grill are found by the comparisons of the flow profiles around the compressor. In addition the unwanted reverse flow is happened for the case of unbalanced inflow and outflow situation. The improved model shows the pronounced flow rate increasement around a compressor. The improved system is realized by the modified inlet ports with balanced outlet.