첩 신호 파라메터 추정 기반 통신 케이블 고장점 탐지에 관한 연구

이춘구, 한슬기, 박진배 et al. · 대한전기학회 학술대회 논문집 · 2009

Reflectometry that has been used to localize faults on a cable is introduced. One of the key point of reflectometry is finding time delay between the incident and reflected signals. In this paper, we propose new reflectometry that use Gaussian enveloped linear chirp signal, and use Kalman filter to estimate frequency rate parameter of the chirp signal. From the estimated frequency rate parameter, we can measure the time delay. In a simulation assuming open ended cable, the proposed method is proved to give a good estimation results.

Cited by 0 works.

Authors