한국형발사체 산화제 탱크용 벤트/릴리프밸브 작동 특성 연구
고현석, 장제선, 김병훈 et al. · 한국추진공학회 학술대회논문집 · 2012
A vent relief valve for oxidizer tank used for liquid propellant feed system of the KSLV-II, ensures oxidizer tank ventilation during filling and its protection from overpressure after filling. To check the serviceability life and operation characteristics, we operated the valve 200 times with the pressurized tank and 200 times with the non-pressurized environment, and measured the valve opening/closing time with respect to the tank pressure and the pilot pressure. The average time of the valve opening at pressurized and non-pressurized tank condition were 0.215 and 0.155 sec, respectively. The valve was operated normally in cryogenic environment, the leakage at the post-test was satisfied to the required specification.