지역난방수의 온도변화에 의한 열배관 피로수명평가 및 관리체계 구축

정성욱, 김형근, Yoon‐Seok Chang et al. · 대한기계학회 춘추학술대회 · 2005

District heating(DH) plant is one of major facility can be used to reduce environmental pollution. The DH pipes transmit the heat and prevent heat loss during transportation, which consists of supply and return pipes, and each pipe is operated under different temperature fluctuation condition. The objectives of this paper are to systematize data processing of transition temperature and investigate its effects on fatigue life of DH pipes. As a result, reliable fatigue life evaluation procedures as well as a relational database management system were established and successfully applied to Korean DH pipes.