내압이 작용하는 고압탄소강배관의 파손에 미치는 감육의 영향
권효성, 남기우 · 대한조선학회 학술대회자료집 · 2011
Fracture behavior and pipe strength are very important to the integrity of energy and ocean structures. The pipes of energy plants and ocean structures are subject to local wall thinning, resulting from severe erosion-corrosion damage. Therefore, evaluation of failure pressure and fracture behavior of pipes in energy plants, ocean structes must be needed for getting integrity of them. In this study, the pipe failure tests were performed on carbon steel pipe with various local wall thinning shapes, wall thinning length, wall thinning depth. The tests were conducted under internal pressure. The results of tests showed that failure mode of wall thinned pipe depended on magnitude of internal pressure and wall thinning length as well as wall thinning depth. The circumferential strain of wall thinned pipe was measured by using strain gage. When circumferential strain was over 0.2%, failure of wall thinned pipe began. and twice of pressure at 0.2% circumferential strain was needed to burst pipe with t/T=0.1, L=102mm. When the pressure was reached at failure pressure, wall thinned area of STS370 pipe burst as a result of plastic behavior with large plastic deformation
Cited by 0 works.