응축형 가스보일러용 열교환기 개발에 관한 연구
유윤석, 변성근, 금성민 et al. · 대한설비공학회 학술발표대회논문집 · 1998
The study was carried out in order to determine design factor of heat exchanger for condensing gas boiler and examine the heat transfer performance. For design of condensing heat exchanger, the design factor of upper and lower fin-type heat exchanger was determined in first by experimental result of model heat exchanger, and detail shape of baffle in lower heat exchanger were determined. And the final condensing heat exchanger was made and performance test was carried out. Therefore, when the load was 20,000 ㎉/hr(equivalence ratio 0.75), NOx emission concentration was below 30 ppm. The heating water efficiency reached to 97% (higher about 12% than heat exchanger of conventional boiler), and hot water efficiency was 102% (higher about 17% than heat exchanger of conventional boiler).