피복텐던을 적용한 원자로건물 포스트텐셔닝 구조효율성 분석
박종혁, 방창준, 김좌영 et al. · 한국건축시공학회 학술.기술논문발표회 논문집 · 2012
Analysis on structural effects which are reduction of friction coefficient and increase of tendon area by HDPE greased and large size strand in post-tensioning system of reactor containment building was carried out. Effective ratio of tendon force increases 67% to 83% by HDPE greased strand and vertical, horizontal internal section forces increased maximum 51%, 41% respectively. Tendon quantity could be reduced 30% by large size and HDPE greased strand that can maintain safety of ultimate internal pressure same as at present.
Cited by 0 works.