룸에어컨 내부 유동 특성에 관한 수치적 연구
서현석, 전현주, 김영재 et al. · 대한기계학회 춘추학술대회 · 2007
At present, many studies on the air-conditioning systems are more focused on the individual thermal comfort than the thermal efficiency due to increase of the concern of health. Numerical analyses were carried out for investigating the flow characteristics in the room, including the impeller, the rearguider, the stabilizer and the blade of the diffuser region in the RAC. Especially, two different types of blade in the diffuser region, single blade and double blades, were numerically estimated. Using a commercial code, FLUENT, two-dimensional steady air thermal flow fields are calculated with different rotating speeds of impeller. The rotational frequency of impeller is located in the range from 900 rpm to 1200 rpm. Turbulence closure is achieved using a standard k-e model. A moving reference frame approach is adopted to simulate the flow field generated by impeller in the RAC. Results are graphically depicted with various geometrical configurations and operating conditions.
Cited by 0 works.