섬유복합모르터의 뿜칠마감에 의한 고강도콘크리트 기둥부재의 폭렬방지

송용원, 한동엽, 이건철 et al. · 한국건축시공학회 학술.기술논문발표회 논문집 · 2006

High strength concrete has been increasingly used in high rise building and it is very obvious to consider fire resistance performance of that. Unlike the normal strength concrete, high strength concrete in sudden elevating temperature at fire is susceptible to spalling with severe explosion and surface split, due to high density of concrete. In order to endure the spalling, inner space temperature of concrete should be control less than certain point. Therefore this study investigated the influence of covering materials on high strength concrete finishing spray-on materials of fiber composite spray mortar(FCSM). Both polypropylene(PP) and polyvinyl alcohol(PVA) fiber were used in this test. Test showed that concrete, covering 18㎜ mortar containing PVA fiber and confining metal lath 2.3㎜ thickness, decreased 50% of main bar ambient temperature, compared with control concrete. In addition, concrete covering 18㎜ mortar without fiber caused falling of covering materials and then it was exposed in elevating temperature. As a result, spalling of the concrete occurred same as control concrete. However, concrete covering spray-on mortar containing PVA or PP fiber resisted spalling occurrence.

Cited by 0 works.

Authors