반도체용 핫플레이트 챔버 내 자연대류가 핫플레이트 표면온도 균일도에 미치는 영향
박준수, 권현구, 조형희 · 대한기계학회 춘추학술대회 · 2007
Effect of natural convention for hot plate surface temperature uniformity was studied by experiments that were adjusted height of chamber and temperature difference. The hot plate chamber is composed of the hot plate and the upper heater and adiabatic vertical wall. The hot plate diameter is 220㎜ and maintains temperature at 150℃. Flow pattern compares with surface temperature and confirms that natural convection affects on temperature uniformity of hot plate surface. In case, temperature non-uniformity of hot plate surface is due to heater pattern, lots of weak and small flow cells more improve temperature uniformity than stronger flow cells or non-developing flow cell. Improve temperature uniformity 1.2℃ when developing weak and small flow cells.
Cited by 0 works.