Диагностика температурного поля контурной тепловой трубы с открытой компенсационной полостью

Афанасьев Валерий Никанорович, А. В. Недайвозов, Якомаскин Александр Алексеевич · Известия высших учебных заведений. Машиностроение · 2014

Heat pipes (HPs) that are widely used in various types of equipment often cannot meet the demands of new technologies. For example, they are very sensitive to their position in the gravitational field because a slight excess of the size of the evaporation zone over that of the condensation zone can drastically reduce their efficiency. Moreover, they have limited transmission capacity and heat transfer distance, which significantly reduces the field of their application. Unlike HPs, loop heat pipes (LHPs) are not subject to these drawbacks but have all major advantages of HPs. A plane LHP model with an open compensation cavity that was developed, designed and experimentally investigated at Bauman Moscow State Technical University is presented. The LHP evaporator is a brass plate with welded ribs and a wick mounted on the plate. The wick material is powder PNS-10. Experimental studies were performed to find the temperature field in a plane LHP with an open compensation cavity, which made it possible to estimate the thermal state of the heat-carrying medium in the loop.

Cited by 0 works.

Authors