스터테반트 공기분급기의 분리효율에 대한 연구
박시우, 정인기 · 2004
This research was performed to raise grade efficiency of Sturtevant type air classifier, to treat powder less than 74 μm particle produced at the crushing process of the dry aggregates manufacturing system or concrete wastes recycling system. The experimental conditions were in the ranges, 0.85 to 5.15 ㎥/s of primary air flow rate. 0.005 to 0.015 ㎥/s of secondary air flow rate, 30˚ to 70˚ of auxiliary blades angle, respectively, for 1.7~3.3 kg/min of the powder feed rate. It was found that the grade efficiency of the air classifier was increased as the baffle plate was attached at the expansion region, and the optimal operating conditions of the air flow rates and the blade angle were obtained. The fractional recovery curves from the experiments were well agreement with the theoretical one of tvlolerus model.
Cited by 4 works.