나트륨 히트파이프의 작동 특성 및 성능에 관한 실험적 연구
유정현, 강환국, 이동찬 et al. · 대한설비공학회 학술발표대회논문집 · 2005
The experimental study for an operational characteristics and performance of the sodium heat pipe were carried out. For an experiment, the heat pipe which is 1000㎜ length and 25.4㎜ diameter of stainless steel container with 50 mesh of screen wick using sodium as a working fluid is manufactured and tested as functions of heat flow rate, inclined angle and operating temperature. The test results are as follows. During the start-up, frontal start up was observed because of the vapor density increasing as increased the hot zone. Also, the heat pipe showed uniform temperature over than 420℃ of the operating temperature. The average heat transfer coefficient increased as the heat flux and the vapor temperature increase, and the range of the total thermal resistance was 0.075-0.04℃/W at the 12-53.55 ㎾/㎡ of heat flux and 500-750℃ of operating temperature. The maximum heat flow rate was 750W at the 10 degree of top heating mode.