순서접속제어에 의한 단상유도전동기의 기동특성
박수강, 성경민, 조금배 et al. · 전력전자학술대회논문집 · 1996
The most common for starting a single phase induction motor is to install a starting condenser and a centrifugal switch in series with the auxiliary winding. Though this method is simple, life of single phase induction motor is short because of malfunction of a starting condenser and a centrifugal switch and efficiency improvement has limitation. In this paper, the starting characteristics of SPIM is improved by sequence voltage control strategy of auxiliary winding in removing a starting condenser and a centrifugal switch. Finally, the excellent starting performance of SPIM is shown through simulation and experimental results.
Cited by 0 works.