벨로우즈를 이용한 반복 하중부과장치의 개발 및 성능시험
최명환, 조만순, 박승재 et al. · 2007
A fatigue capsule is one of the special capsules to investigate the fatigue characteristics of the nuclear materials during an irradiation test in a research reactor, HANARO. In this study, the performance test and the preliminary fatigue test results by using a cyclic load device newly developed for a fatigue capsule are described. In order to obtain the characteristics such as a realization and a controllability of the periodic wave shape and the relationship between the pressure and the load, a spring and rigid bar specimens are used. The fatigue test for the 316L stainless steel specimen with 1.8㎜ in diameter and 12.5㎜ in gage length is also performed under the same conditions as the temperature(550 ℃) of the specimen during irradiation tests. As a result of the test, the fracture of the specimen occurs at a total of 70,120 cycles (about 12 days), and the displacement in this case is 2.02 ㎜. It is expected that these results will be used for determining test conditions and a comparison of the in-pile fatigue test results.
Cited by 0 works.