핵연료봉과 증기발생기 전열관의 마멸기구에 대한 실험적 고찰
이영호, 김형규 · 대한기계학회 춘추학술대회 · 2006
Experimental investigation of fretting wear behavior in room temperature air and water was performed to compare the wear mechanism between nuclear fuel rod (Zirconium alloy) and steam generator tube (Ni-based alloy, Inconel). The main focus is to evaluate the fretting wear mechanism room temperature air and water.. Test conditions are 10 ~ 50 N of normal load, 10 ~ 210 m of sliding amplitude and 30 ㎐ of frequency. The result indicated that the fretting wear behavior of the nuclear fuel rod depends on the contact condition and debris behavior within contacting surfaces. However, that of the steam generator tube was influenced by the surface or subsurface deformation. This is due to the solid-to-solid contact. From the results of OM and SEM observation, wear mechanism of both nuclear fuel rod and steam generator tube depended on both the contact condition and test environment.
Cited by 2 works.