철도신호 시스템에서 공동접지에 따른 기기상호영향에 관한 연구
유광균, 홍효식, 노성찬 · 한국철도학회 학술발표대회논문집 · 2010
Safety and reliability of computerization and electronic railway signal system is more influenced by abnormal voltage which is surge, lighting ect. It demand on improvement of protective equipment or grounding system performance to protect a signalling system by abnormal voltage. The common grounding system which is compensate the independence grounding system defect is contribute to improvement of protective performance for railway signal system which was introduced with the high speed railway. The common grounding system using a buried earth cable is configuration to a network with a railway signal system and a communication system, a power distribution system etc, which is suppressed a grounding potential versus a independence grounding system. This paper will present a frequency characteristic of grounding impedance on common grounding system using a buried earth cable and a frequency characteristic transition of grounding impedance when the only uses a buried earth cable and uses a buried earth cable with ground rods.