고무차륜형 경전철 고가구조물의 충격계수 계측시험연구

신정열, 이안호, 박재임 et al. · 한국철도학회 학술발표대회논문집 · 2013

Unlike the steel-wheeled rail transit of conventional railway including high-speed railway, the design guideline of elevated structures for rubber-tired rail transit has not been established in Korea. For this reason, the elevated structures of rubber-tired light rail transit have been designed and constructed based on the design code of conventional heavy railway bridges or on the one suggested by foreign rolling-stock manufacturer. This is why the elevated structures of rubber-tired rail transit in Korea are much massive, or over-designed and non-economically constructed. In Korea, design engineers have no way but to refer to the standard of roadway for considering the dynamic effect of rubber-tired light rail transit. Therefore, in this paper, as the basic study on the design guideline of elevated structures for rubber-tired light rail transit, authors carried out the field test to analyze the dynamic factor of elevated structures, which induced by the driving train at the speed of 5km/hr, 10km/hr to 70km/hr. Authors also briefly demonstrate the test and analyzing results of dynamic factor acting on the superstructures of elevated light-rail structures.

Cited by 0 works.

Authors