전기화학적 전착기법을 활용한 콘크리트의 인공 균열치유에 관한 실험적 연구

이창홍, 송하원 · 2009

In this study, autogenous crack healing and artificial crack healing using electrochemical electro deposition method were conducted to compare in the aspects of corrosion monitoring. Furthermore, the analysis of impressed voltage characteristics, galvanic current and linear polarization resistance comparison, and photo image processing technique were performed for quantitative comparisons of healing ratio. As a result, it was found that, in view of impressed voltage of artificial crack healing, the measured voltage was increased as time goes by. From the galvanic test results of artificial crack healing, the current vs. potential distribution value were formed widely in comparison with autogenous crack healing. In this point, it was shown that artificial crack healing has more eleatic resistance capacity than autogenous crack healing technique. Finally, it was found that artificial crack healing was 1.63 times higher than autogenous healing in view of crack healing ratio.