매립가스 마이크로가스터빈 배가스 분석에 관한 실험적 연구

박정극, 허광범, 임상규 et al. · 2011

MGT fuelled by landfill gas was tested to asses feasibility of its exhaust gas application for CO₂ enrichment. The exhaust gas was analyzed during start-up and normal operation with different MGT load conditions. Due to the changes of air/fuel ratio and combustion mode, O₂, CO₂, CO and NOx concentration were varied within wide ranges during the MGT start-up. Especially, NOx emissioin level was increased up to 20.01 ppmv. Different tendencies of O₂, CO₂, CO and NOx concentrations were observed with MGT output changes. O₂ and CO concentrations were shown to be decreased and NOx and CO₂ concentrations were shown to have opposite trends. NOx emission level (0.8~1.88 ppmv) was very low compared to other types of combustion based power generation equipment. Unburned hydrocarbon emission level was substantially decreased with MGT load increase. Especially, C₂H₄ concentration was below the detection limit(0.2 ppmv) around the nominal load condition. The exhaust gas from landfill gas fuelled MGT system was shown to be feasible for CO₂ fertilization. Concentrations of major components were within or below the maximum allowable ranges.