밀폐형 2상 열사이폰의 불안정 핵비등영역에 관한 실험적 연구

강환국, 박지만, 김철주 et al. · 대한설비공학회 학술발표대회논문집 · 1995

The oscillatory behavior of tube wall temperature and working fluid for a closed two-phase thermosyphon which has operated under pulse boiling process is studied. The magnitudes of pulse period, and the degree of superheat of working fluid are measured using an ethanol thermosyphon, which was made of a copper tube of length of 1000㎜ and diameter of 16㎜. In this study, the effect of heat flux, vapor pressure and fill charge rate, imposing in pulse period and superheat of liquid pool are also examined. The operation condition, at which a thermosyphon might undergo a pulse boiling process, would be determined by a correlation formula, 1200v^(0.0284) <q^N<1200Pv^(0.45) which is taken from the results of a map of boiling regime data. The experimental results also show that the pulse period magnitude during 10 to 200sec decreases smoothly, depending on heat flux and vapor pressure, but the fill charge rate seems to impose a minor effect on it.