마이크로 기둥 압축 시험에서의 오차요인에 관한 수치 해석 연구

Jae Hyun Kim, 이학주, 최병익 · 대한기계학회 춘추학술대회 · 2007

Micro-scale structures are extensively utilized in many devices including MEMS, NEMS, opto-electronic devices, bio-medical devices, etc. To design those devices, we need to measure the mechanical behaviors of the micro-scale structures. There are intensive research activities in mechanical characterization of the micro scale structures based on micro tensile test, nanoindentation, blistering test, strip bending test, pillar compression test, etc. These tests often lead to inaccurate test results due to alignment error, calibration error, environment error, model error, etc. In this study, we focus on pillar compression test and investigate error sources using finite element analysis. The effects of aspect ratio of pillar, frictional boundary condition, alignment, Poisson's ratio on the measurement errors are quantitatively estimated. Guidelines for compression test of micro pillar are described for minimizing these errors.

Cited by 0 works.

Authors