발전기 회전자 권선의 건전성 평가
이영준, 주영호 · 대한전기학회 학술대회 논문집 · 2006
A shorted-tum test was performed at the Pyungtaek combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line shorted-tum diagnosis system. The permanent flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-tum with n each slot.
Cited by 0 works.