도시형 자기부상열차 대차 프레임의 정적 강도 평가

한정우, 이종민, 방제성 et al. · 한국철도학회 학술발표대회논문집 · 2012

This study presents that a static test method of bogie frame was developed considering characteristics of maglev train itself and possible occurring loads and then static strength for the bogie frame of Korean maglev evaluated experimentally through the static test. The results of the static test showed that the highest stress was measured at a connecting part of casting block and side frame as the result of electromagnet cling load test. When evaluating static strength based on yield strength, it is found to be within safety side. And also all stress levels measured do not exceed the yield strength of the used material.