전철선로 임피던스계산에 관한 연구

이춘배, 김왕곤, 이종우 · 2004년도 추계학술대회 논문집 · 2004

Impedance calculations of electric railway traction systems is essential to define characteristics and to design it.The self impedance is defined voltage drop rate per unit length, the mutual impedance is represented as a voltage induced to transmission line from transmission line . The self and the mutual impedance are influenced by ground return currents. The earth is considered as a semi-infinitely extended non-ideal conductor. The current of transmission line produces earth current induced magnetically and it flow through a path having minimum impedance. Carson proposed the impedance calculation formula using wave equations and magnetic field equations. Though the formula have an improper equation, that is still used as a standard impedance calculation method. This paper introduced an impedance calculation method that the complex depth of earth return method assumes that the current in conductor returns through an imagined earth depth path located directly under original conductor at a depth of . In this paper, we showed that this proposed method has a closed form and is easier than Carson 's.

Cited by 0 works.

Authors