고역률 사이크로 컨버터의 매핑함수제어

김천식, 김광태, 서기영 et al. · 전력전자학술대회논문집 · 2000

A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current. unity input displacement factor regardless of load power factor Moreover, compensation of the asymmetrical and harmonic containing input voltage is sautomatically realized, and calculation time of control function is reduced.

Cited by 0 works.