추진제어장치 동작 중 궤도 점유 회로 오류 방지 대책
권일동, 이광국, 김명한 et al. · 한국철도학회 학술발표대회논문집 · 2009
It often happens that the position indication of EMU(Electric Multiple Unit) is not possible from a malfunction of specified components by a factor of flow such as harmonic current at a track occupied circuit. Especially, a common factor can be included at the return current generated during operation of propulsion system because DC input voltage is inputted from rectifier via transformer and it is easy to have a malfunction of a component (relay) has a factor of the common as an operating source. Here, current detected through using and extra current transformer and sensing circuit to measure the return current when operating can be extracted into the current of common by Algorithm for extracting the factor of specified frequency on the propulsion system of DC line voltage applied to EMU. It has the purpose that is to minimize a malfunction of the relay in track occupied circuit as applying real time monitoring and protection logic by setting a criterion level.