철골 플레이트 커플링보 접합부의 내진성능

송한범, 염찬희, 이경훈 et al. · 대한건축학회 학술발표대회 논문집 - 구조계 · 2006

The coupling beams must yield before the wall piers, behave in a ductile manner, and exhibit significant energy dissipation characteristic. And owing to higher story tendency and ceiling hight restriction of recent times, even though the depth of Coupling Beam decreases the demand efficiency is coming to be high rather so it is the difficult to satisfy a demand efficiency with the actual existing RC/Steel condition. To achieve these demands for coupling beams, embedded steel plate coupling beam is proposed. And to achieve better ductility and energy dissipation, steel-plate coupling beam embedded in the reinforced concrete beams attached stud bolt is studied. A comprehensive experimental test involving 4 steel-plate coupling beam specimens has been performed and results from this program are used herein to study the performance of each details of steel-plate coupling beams embedded in the reinforced concrete beams.

Cited by 0 works.