강제대류에서 열전모듈의 냉방 성능에 대한 연구

신재훈, 한훈식, Yoon‐Ho Kim et al. · 대한기계학회 춘추학술대회 · 2009

The thermal performance of a thermoelectric module in a thermoelectric cooling system with a heat sink is analytically and experimentally examined. The thermoelectric cooling system is composed of a thermoelectric module and two heat sinks. The thermal performance of a thermoelectric module (Seepel, Crystal) is analytically taken into account. The results show that COP (coefficient of performance) of a thermoelectric module is reduced and the heat absorbed increases as the input voltage increases. The thermoelectric cooling system with 12V provides 73.3% lower COP and 46.7% higher heat absorbed compared to 5V, experimentally. The theoretical predicted result is in good agreement with the measured data.