공동주택 급탕에너지 사용량 분석을 통한 태양열 급탕 시스템 적용성 검토
김원석, 오병길, Byung Seok Lee · 대한설비공학회 2015년도 하계학술발표대회 · 2015
A study on the application of solar thermal hot water system was carried out by using analysis of the hot water energy consumption in apartment buildings. Optimal collector area of solar hot water system was studied to protect the overheating of the system and applicate solar system in apartment buildings. As a results, hot water consumption in apartment buildings was varied inversely with the variation of the ambient temperature. and the monthly hot water consumption was up to 2.5 times(max/min hot water consumption rate) the difference. Besides, daily hot water consumption of household unit was from 0.095 to 0.23 m³/day. hot water consumption of household unit was proportionally increased with the area of household unit(101 m² → 0.079 m³/day, 207 m² → 0.112 m³/day). The area of solar collector was required from 2.25~3.11 m² in area of household unit(101~207 m²) to cover the hot water consumption in August.