열전냉각시스템 냉각영역의 성능개선을 위한 압전구동기 적용에 관한 연구

윤희성, 최제세, 오율권 · 한국자동차공학회 추계학술대회 및 전시회 · 2009

This study investigated on performance improvement of cooling region in thermoelectric cooling system when piezoelectric actuator was applied. In this study, piezoelectric actuator was used for generating vibration in cooling region of thermoelectric cooling system. When vibration was generated by the piezoelectric actuator, temperature distribution was measured using thermocouples for investigating cooling characteristics in cooling region of thermoelectric cooling system. Also, He-Ne laser and CCD camera were used for flow visualization in cooling region. The experimental set-up for temperature measurement and the flow visualization in cooling region consisted of thermoelectric cooling system, piezoelectric actuator, thermocouples, data acquisition units, He-Ne laser, CCD camera, image grabber and PC. As a result, it was certified that vibration of piezoelectric actuator generated forced convection, and the cooling efficiency in the cooling region was improved when piezoelectric actuator was applied.

Cited by 0 works.

Authors

References