온도 변화에 따른 기포펌프의 수직관내 이상유동과 성능특성

이광성, 김진화, 김미화 et al. · 대한기계학회 춘추학술대회 · 2009

A study on the two-phase flow and performance characteristics in the tube according to temperature in bubble pump system presented in this paper. For the experimental facilities composed of electrical heater used for provide heat source to generate bubble, a vertical tube with diameter of ?8㎜, length of 500㎜, Storage tank with capacity of 40Liter and heat exchanger. The separator and condenser of the air bubble pump were installed separately. As results, air bubble occurred within 50~60 ℃ but it was stagnate in the tube no moving. However, the heating temperature maintained within 70~80℃ then bubble flow occurred and flowing to upward. Consequently, from 80℃ temperature condition the slug flow happened and the flow velocity located within 7.69~14.28 ㎝/sec and the thermal amount of storage tank as 9280㎉.

Cited by 0 works.