수평관내 이산화탄소의 증발 열전달 특성에 관한 연구
최선묵, 손창효, 이동건 et al. · 한국마린엔지니어링학회 학술대회 논문집 · 2004
The evaporative heat transfer characteristics of carbon dioxide in a horizontal tube investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which driven by a magnetic gear pump. The main components of the experimental facility are a magnetic gear pump, a receiver, a mass flow meter, a pre-heater and evaporator(test section). The test section is a stainless steel tube of 7.75mm in I.D. and 5000mm in length, which was heated by an electric coil heating method. The experiment were conducted at mass flux of 200 to 400kg/㎡s, saturation temperature of -5℃ to 5℃, and heat flux of 10 to 30kW/㎡. The test result presents the evaporative heat transfer coefficient of carbon dioxide decreases as vapor quality increases. For all the experimental conditions, the heat transfer coefficient of carbon dioxide has an effect on more heat flux than mass flux. In comparison with test results, existing correlations failed to predict the evaporative heat transfer coefficient of carbon dioxide, therefore, it is necessary to develope reliable and accurate methods determining the evaporative heat transfer coefficient of CO₂ in a horizontal tube.