수치해석 격자 및 화원 위치가 도로 터널 임계속도 산정에 미치는 영향

이승철, 전우철, 박영록 et al. · 대한기계학회 춘추학술대회 · 2011

To estimate the critical velocity in road tunnel fire, this study calculated one-dimensional equation and conducted three-dimensional computational fluid dynamics, varying the grid number and the location of the fire source. 8 kinds of numerical analysis were carried out. The critical velocity in the target tunnel by one-dimensional way, 2.22 ㎧ was calculated, when hydraulic diameter was applied instead of the tunnel height. According to six numerical analysis, each grid number has different position, temperature, and CO concentration of backlayering. In the Case of the subject, 0.8 million grid was found to be the most ideal. According to three numerical analysis, the location of the fire source affect the critical velocity, through the different air velocity, temperature, and CO concentration distribution of each Case. This solution is considered to be caused by the different buoyancy force according to the density gradient of stratification.