소형 열펌프 건조기의 건조특성에 관한 실험적 연구

김영득, 이성재, 권준호 et al. · 대한설비공학회 학술발표대회논문집 · 2015

Drying characteristics of small heat pump type dryer for farm products is studied through decision of optimum refrigerant quantity in dryer and comparative experiment of heat pump and electrical heater dryer and their conclusions are follows ; The optimum refrigerant quantity is 2.2 kg and it is decided by evaporation loss test according to refrigerant quantity. Temperature difference in dryer is controlled within 3℃ in lower, middle and upper zone and air quantity at air outlet of lower part in dryer is increased for that. Heat pump performance is changed with indoor temperature and we need dryer test standard. Drying Efficiency of heat pump is high 58%. But drying capacity is lower than 2 kW and it is due to lacking optimun refrigerant quantity and low evaporator temperature. So it is necessary to increase evaporator temperature to 5~10℃. And it is necessary to test comparative test of heat pump and electrical heater in high temperature from now on.

Cited by 0 works.