염공부하에 따른 세라믹 화이버 버너의 배기 배출물과 분광학적 특성에 관한 연구

정용기, 이대래, 김영수 et al. · 대한기계학회 춘추학술대회 · 2007

An experimental study was performed to investigate the effects of both non-perforated and perforated ceramic fiber mat on temperature, CO, NO emission and radiation characteristics in porous ceramic fiber radiant burners. Observations of combustion characteristics occurring inside the burner system which was insulated fiber mat, were investigated by measuring emission and radiation characteristics. Combustion was achieved at the excess air ratio of 0.9~2, heat capacity of 1000~3000㎉/h. The local temperature distribution inside the mat and near the glass surface as a function of the equivalence ratio can be reasonably interpreted by the relation of the heat balance in the mat and movement of the reaction zone. CO emissions were found to be strongly dependent on the operating conditions. There was a tendency that CO concentration decreased as the excess air ratio increases. The NO concentration is maximal at the excess air ratio of approximately 1. The both fiber burner exhibit significant both spectral intensity peaks in the bands at 2.5㎛ and 4.0㎛ relatively.

Cited by 0 works.