감육 곡관의 손상압력에 미치는 하중제어 굽힘하중의 영향
김진원, 윤민수 · 대한기계학회 춘추학술대회 · 2010
This study performed burst test using real-scale pipe specimens with local wall-thinning under combined internal pressure and a constant bending moment, to evaluate the effect of load-controlled bending load on the failure pressure of local wall-thinned pipe bend. In the experiment, the 90-degree elbows of 63㎜, Sch.80 with wall-thinning defect were considered as a pipe specimen. Extrados and intrados wall-thinning subjected to both opening- and closing-mode bending were regarded. The experimental results showed that load-controlled bending clearly reduces failure pressure of wall-thinned pipe bend, in contrast to displacement-controlled bending reported from the previous study. The bending load effect was more significant under opening mode bending than under closing mode bending. Also, the effect was considerable for intrados wall-thinning case.