천연가스 수송배관의 위험평가

조영도, 박교식, 김지윤 · 한국가스학회 학술대회논문집 · 2004

Unlike other hazardous plant, the transmission pipelines carrying natural gas are not within secure industrial site, but are routed across land out of owned by the pipeline company. If the natural gas is accidentally released and ignited, the hazard distance associated with these pipelines to people and property is known to range from under 20 m for a smaller pipeline at lower pressure, up to over 300m for a larger one at higher pressure. Therefore, pipeline operators and regulators must address the associated public safety issues. This paper focuses on a method to calculate explicitly the individual risk of transmission pipeline carrying natural gas with reasonable accident scenarios for route planning related to the pipelines proximity to surrounding building. The minimum proximity distances between pipelines and buildings is based on the rupture of the pipeline and the distances where chosen to correspond to a radiation level of approximately 32 ㎾/㎡. In the design criteria of steel pipelines for high pressure gas transmission(IGE/TD/1), the minimum building proximity distances for rural area are located between 10?? and 10?? of individual risk. Therefore, the risk from natural gas transmission pipeline is low comparing with other risk from traffic or chemical industries.

Cited by 0 works.

Authors