The purpose of this study is to investigate punching shear strength of exterior flat plate slab supported by rectangular column, with respect to column aspect ratio varied between 2.0 to 4.5. To inspect the effect of column aspect ratios on the punching shear behavior, the length of critical shear section was held constant(β o =b o /d≒20). Six flat plate slab specimens connected to normal and high strength concrete column having aspect ratio between 2.0 and 4.5 have been made and tested. As increased column aspect ratios, the punching shear strengths are decreased but the reducing values were not much than KCI and ACI Code's prediction in the column aspect ratio over 3.5.